Equipment Packages
There are many equipment solutions available depending on the application. Our standard equipment packages include all venting, nozzles, plumbing, adapters, valves and pumps that represent the industry standard in handling of flammable and combustible liquids. The listed equipment below is a sampling of equipment available and represents some of equipment considerations for your application. If you don't see what you need, we'll help you get the equipment or refer you to a dealer that can meet your needs.
Standard Small Tank Package Up to 1000 Gallon Capacity
Standard Small Tank Package Up to 1,400 Gallon Capacity
  • Fuel pump, meter and totalizer (110VAC/18gpm) with pick up tube & filter assembly
  • Upgraded auto shutoff nozzle for leaded/diesel with swivel and breakaway
  • Emergency vents & atmoshperic double outlet vents with extensions to 12'
  • Lockcable fill cap
  • UL Listed
Standard Small Tank Package 1500-4000 Gallon Capacity
Standard Small Tank Package 1,500-4,000 Gallon Capacity
  • Fuel pump, meter and totalizer (110VAC/15gpm) with pick up tube & filter assembly
  • Upgraded auto shutoff nozzle for leaded/diesel with swivel and breakaway
  • Emergency vents & atmoshperic double outlet vents with extensions to 12'
  • Lockable fill cap
  • Overfill prevention valve with 2" cam lock adapter and dust cap
  • Fill spill container
  • Remote Kit: anti-siphon valve and plumbing required to relocate the pump to the side of the tank
  • UL Listed
Standard Large Tank Package Greater Than 5000 Gallon Capacity
Standard Large Tank Package Greater Than 5,000 Gallon Capacity
  • Fuel pump, meter and totalizer (110/220 VAC 1-phase/30gpm) with pick up tube & filter assembly
  • Upgraded auto shutoff nozzle for leaded/diesel with swivel and breakaway
  • Emergency vents & atmoshperic double outlet vents with extensions to 12'
  • Overfill prevention valve with 3" cam lock adapter and dust cap
  • Remote Kit: Anti-siphon valve and plumbing required to relocate the pump to the side of the tank
  • UL Listed
Optional High Volume Large Tank Package Greater Than 5000 Gallon Capacity
Optional High Volume Large Tank Package Greater Than 5,000 Gallon Capacity
  • Submersible pump (230V/1phase) available in 1/3 hp, 3/4 hp, 1 1/2 hp, and 2 hp
  • Overfill prevention valve with 3" cam lock adapter and dust cap
  • Upgraded auto shutoff nozzle for leaded/diesel, swivel, breakaway and hose
  • Emergency vents & atmospheric double outlet vents with extensions to 12'
  • Dispenser Kit: dispenser with meter & totalizer, filter, anti-siphon valve and plumbing required to locate to the side of the tank
  • UL Listed
    Please Contact Us For Custom Pricing
Other Equipment
Vent Kit Package
Vent Kit Package
  • Emergency Vent
  • Atmospheric Vents
  • Fill cap for small tanks
Overflow Prevention Kit
Overflow Prevention Kit
  • Accessories required to install an overfill prevention valve
  • This is required for accessory for tanks with 4,000 gallons or higher capacity
FR701v

Fuel Transfer Pump FR701
  • Factory rating of 20GPM (varies with application)
  • 1/2 HP 115VAC
  • Meter and register
  • 30 min duty cycle
  • Pump may be padlocked
  • Compatibility: diesel, gasoline, mineral spirits, solvent, heptanes
  • UL & cUL listed

FR311vb

Fuel Transfer Pump FR311
  • Factory rating of 35GPM (varies with application)
  • 3/4 HP Dual voltage: 115/220 VAC 1-phase
  • Meter and register
  • 30 min duty cycle
  • Pump may be padlocked
  • Compatibility: diesel, gasoline, mineral spirits, solvent, heptanes
  • UL & cUL listed

Sub-Pump

Submersible Turbine Pump
  • Horsepowers Available:
    (230V/1-phase) 1/3 hp, 3/4 hp, 1 1/2 hp, and 2 hp
  • Fuel Compatibility: Diesel, Gasoline, Ethanol, Methanol
  • UL cUL listed

Remote Dispenser

Remote Dispenser
  • From 6 to 40 GPM
  • Meter and register
  • 110/230 VAC 60Hz

Overfill Prevention Valve

Overfill Prevention Valve
  • Installed at the fill port
  • Shuts off the flow of product when the liquid level reaches a preset warning level (90 - 95% full)
  • This Valve Complies With the Following Codes: NFPA 30, 30A, UFC, BOCA, SBCCI/SFC and PEI /RP2000

Gauges
Gauges
  • For measuring liquid level in aboveground storage tanks
  • Gauge mounts on top of tank and is commonly activated by a float connected to a cable
  • Many options available depending on application requirements and budget
Atmospheric Venting

Atmospheric Venting
  • Aluminum T style vent with double outlet ports on either side of the inlet with stainless steel screen keeps debris out of the airway
  • Vent allows pumps to operate during filling and dispensing operations

Fill Caps

Fill Caps
  • Loose-seal style aluminum cap with hinged cover
  • For fill port of small storage tanks
  • Lockable with a padlock
  • Other fill caps available

Emergency Vent

Emergency Vent
  • Emergency Vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and rupturing if exposed to fire

Anti-siphon Valve

Anti-siphon Valve
  • Used on above-ground storage tanks to help prevent a release of product if a rupture in the line occurs below the liquid level in the tank
  • This valve is normally closed and will resist the head pressure and assist in preventing any drain off of tank contents


ulscopyrights2008 Eagle Tanks, Inc., All Rights Reserveds email us Email Us sCall Us For A Quote: 1 (888) 678-0698